1" Low Pressure Gas Solenoid Valve - N/O
Technical Details
Product Overview
The BCM-25K is a heavy-duty 1" brass solenoid valve engineered for high-flow, low-pressure, and zero-differential gas control applications. Featuring an internal mechanical spring assist and a flexible NBR diaphragm, this valve guarantees a positive, airtight seal at 0 PSI where standard pilot-assisted solenoid valves fail to function.
Important Application Notice:
-
-
- This valve is Normally Open (remains open when de-energized and closes when powered). It is not suitable for primary fuel-gas safety shutoff, as power loss will allow gas to flow.
- This configuration is specifically intended for specialized setups such as double-block-and-bleed vent lines, high-capacity purge manifolds, and atmospheric relief systems.
-
Key Features
-
Zero Differential Operation: Direct-assist spring mechanism ensures reliable seating under zero line pressure or minimal differential.
-
Normally Open Configuration: Remains open when de-energized to provide immediate, unrestricted venting during power failures.
-
Heavy-Duty Construction: Solid brass body, stainless steel internal components, and nitrile (NBR) seals optimized for natural gas, propane, and inert gases.
-
High Volumetric Flow: Full 1" female NPT ports designed to accommodate high flow rates in industrial gas headers and vent trains.
Common Applications
- Main atmospheric vent/bleed legs in NFPA 86 and CSD-1 double-block-and-bleed burner trains
- High-volume low-pressure natural gas and propane ventilation manifolds
- Industrial boiler, kiln, and thermal oxidizer pressure relief lines
- Large-scale inert gas blanketing (Nitrogen, Argon) and distribution systems
- Heavy process equipment purge and emergency exhaust systems
Installation Note
- This valve is directional.
- Align gas flow with the directional arrow cast into the brass body. Backpressure or backflow will disrupt the internal diaphragm balance and prevent proper sealing.
- Always verify gas compatibility, operating pressures, and local mechanical safety codes before installation.
Wiring Instructions
- Loosen and remove the Phillips-head screw securing the DIN connector to the coil.
- Detach the DIN connector from the coil.
- Open the DIN connector housing by prying at the small slot located in the bottom corner next to the Earth terminal.
- Inside the housing, locate the screw terminals:
- Terminal 1: Connect the hot or positive wire.
- Terminal 2: Connect the neutral or negative wire.
- Earth Terminal (for AC voltages only): Connect the ground or Earth wire.
- Ensure all screw terminals are securely tightened for a reliable connection.
- Reassemble the DIN connector by reversing the steps above.