3/8'' 24V AC Electric Stainless Steel Solenoid Valve N/O
Technical Details
Product Overview
The SZW-10K-24VAC is a heavy-duty 3/8" 304 stainless steel solenoid valve engineered for fail-open, zero-differential fluid control in 24V AC low-voltage systems. Featuring a Viton® (FKM) diaphragm seal and a direct-assisted lift mechanism, this 2-way Normally Open (N/O) valve remains open when de-energized to permit unrestricted flow at 0 PSI, closing in less than one second when 24V AC power is applied.
Normally Open Application & Media Notice:
-
-
- This valve is Normally Open (remains open when de-energized and closes when energized). It is designed specifically for fail-open setups, gravity-fed drains, freeze/overheat protection loops, and safety bypass lines.
- Equipped with a Viton® (FKM) diaphragm rated for media up to 250°F, diesel fuel, glycol, weak acids, and harsh fluids.
-
Key Features
-
304 Stainless Steel & Viton® Construction: High chemical, corrosion, and temperature resistance for aggressive media, potable water, and industrial environments.
-
Normally Open (Fail-Open) Operation: Keeps fluid flowing or lines drained during power interruptions—essential for emergency dump lines and freeze-protection circuits.
-
24V AC Low-Voltage Control: Integrates directly with standard HVAC transformers, Building Management Systems (BMS), and irrigation controllers using an IP65-rated DIN electrical connector.
-
Zero Differential Operation: Direct-assisted design operates reliably from 0 PSI (gravity feed) up to maximum working pressure.
-
Fast-Acting & 100% Duty Cycle: Closes in under one second when energized and rated for continuous-duty operation.
Common Applications
-
HVAC equipment, solar thermal overheat dump lines, cooling loops, and humidification drains
-
Gravity-fed water tank drains, reservoir dumping, and agricultural irrigation flushes
-
24V AC automated hydroponics, fertigation loops, and liquid chemical bypass manifolds
-
Commercial beverage equipment, steam loops, and high-temp sanitizing dump lines
-
Building Management Systems (BMS), compressed air dump loops, and process water lines
Installation
- Align media flow with the directional arrow cast into the 304 stainless body.
- Connect 24V AC power using the included DIN electrical connector.
- For optimal service life and reliable seal closure, especially in gravity-fed drain lines, mount the valve with the coil facing upward.
- Install an inline strainer upstream to keep sediment off the Viton® diaphragm.